Account

What new tool do you want?

Science & Engineering

Pipe Flow Rate Calculator

Calculate flow rate from pipe diameter and velocity (or velocity from flow), in L/min, GPM and m³/h, plus the Reynolds number for water.

How to use

  1. 1Enter the pipe's inner diameter.
  2. 2Enter the flow velocity to get the flow rate, or the flow rate to get the velocity.

How it's calculated

Q = A × v, with A = π d² ÷ 4. Reynolds number Re = v d ÷ ν (ν ≈ 1.0 × 10⁻⁶ m²/s for water at 20 °C); Re > 4,000 is turbulent.

Frequently asked questions

What velocity is typical in water pipes?

Around 1–2.5 m/s (3–8 ft/s) in household plumbing. Higher speeds cause noise, erosion and water hammer.

Should I use inner or outer diameter?

The inner diameter — the actual flow area.

What does the Reynolds number tell me?

Whether flow is laminar (Re < 2,300), transitional, or turbulent (Re > 4,000), which affects friction losses.

Why flow rate grows with the square of diameter

Flow rate is cross-sectional area times velocity, and a pipe's area (π d² ÷ 4) scales with the square of its diameter — so doubling a pipe's diameter at the same flow velocity doesn't double the flow rate, it quadruples it. That's why a modest increase in pipe size can dramatically boost how much water a system can move, and why undersized pipes create such a noticeable bottleneck.

A worked example, including a surprising Reynolds number

A 25 mm (inner diameter) pipe carrying water at 1.5 m/s has a cross-sectional area of π × 0.025² ÷ 4 ≈ 4.909 × 10⁻⁴ m², giving a flow rate of roughly 44.18 L/min. Its Reynolds number — velocity × diameter ÷ kinematic viscosity, or 1.5 × 0.025 ÷ 1.004×10⁻⁶ ≈ 37,350 — is well above the 4,000 threshold for turbulent flow. That's worth noting because 'turbulent' sounds chaotic or problematic, but it's actually the normal operating condition for ordinary household plumbing at typical velocities — laminar flow (Re below 2,300) is the exception in real plumbing, found mainly at very low flow rates or in very narrow tubing.

Why the 1–2.5 m/s guideline exists

Flow velocities above that range in household plumbing tend to cause audible noise, accelerated erosion of pipe walls and fittings, and water hammer — the loud bang that happens when a fast-moving column of water is suddenly stopped by a closing valve and its momentum has nowhere to go but into the pipe walls. Sizing pipes to keep velocity in the recommended range balances adequate flow against these mechanical and acoustic problems.

The highlighted line flips when I already know the flow

Diameter is in millimetres, default 25, and the value box starts at 1.5 as a velocity in metres per second, so flow rate is the highlighted answer, about 44 litres per minute. If I switch the selector to flow rate in litres per minute, that entry is turned into cubic metres per second and velocity becomes the highlighted line instead. Gallons per minute use a factor of about 15,850 per cubic metre per second, and cubic metres per hour are the cubic-metre rate times 3,600. The Reynolds number uses water's kinematic viscosity of 1.004 millionths of a square metre per second, slightly tighter than a round 1 millionth. Above 4,000 the hint says turbulent, below 2,300 laminar, and between them transitional. Diameter has to be greater than zero.

Related tools

More: Science & Engineering