Science & Engineering
Decibel Calculator
Add sound levels in decibels, find the difference between two levels as a ratio, and convert between dB and power or amplitude ratios.
How to use
- 1To add sources, list their dB levels separated by commas.
- 2To compare, enter two levels to see the power and loudness difference.
How it's calculated
Combined level = 10 log₁₀(Σ 10^(Lᵢ/10)). Power ratio = 10^(ΔdB/10); amplitude (pressure) ratio = 10^(ΔdB/20). +10 dB sounds roughly twice as loud.
Frequently asked questions
Is 60 dB + 60 dB = 120 dB?
No — two equal sources add 3 dB, so 60 + 60 dB = 63 dB.
How much louder is +10 dB?
10× the sound power, and perceived as roughly twice as loud.
What levels damage hearing?
Prolonged exposure above about 85 dBA can cause hearing loss; above 120 dB can cause immediate damage.
Why decibels can't be added like ordinary numbers
The decibel scale is logarithmic — it compresses an enormous range of actual sound power into manageable numbers — so combining two sound sources means converting each back to actual power, adding those, and converting the sum back to decibels, not simply adding the dB figures themselves. That's the entire reason 60 dB + 60 dB isn't 120 dB: two equal sound sources only double the actual power, and doubling power on a logarithmic scale adds just 10 × log₁₀(2) ≈ 3.01 dB.
Worked example: Decibel Calculator
Two 60 dB sources combine to 10 × log₁₀(10^6 + 10^6) = 10 × log₁₀(2,000,000) ≈ 63.01 dB — a 3 dB bump, not a 60 dB one. Separately, a 10 dB difference between two levels (say 70 dB vs. 80 dB) represents a 10^(10/10) = 10× difference in actual sound power, but is typically perceived as only about twice as loud — the loudness-doubling figure is a separate, empirically derived psychoacoustic approximation (not every listener perceives it identically), while the power ratio is an exact mathematical consequence of the dB definition.
Why hearing damage thresholds are stated in dB, not watts
Because decibels compress such a vast range of actual power into a linear-feeling number line, a jump that looks small on paper — say from 85 dB to 100 dB — actually represents over 30 times more sound power hitting your eardrum. That's exactly why hearing-safety guidelines (prolonged exposure above ~85 dBA risking long-term damage, above 120 dB risking immediate harm) treat every few decibels as a meaningfully bigger step than the number alone suggests.
Commas, spaces, and semicolons all split the list
The add-levels box starts as 60, 60, 55, not a pair. I can separate levels with commas, spaces, or semicolons, and a single number such as 90 simply comes back as 90, which is a useful check that nothing is being added when only one source is present. Anything that is not a number in that list stops the calculation and asks for levels separated by commas. The combined result is the only output that always appears. The comparison block, difference, power ratio, and perceived-loudness ratio, shows up only when both comparison levels are actual numbers. If I clear one of them, those three lines disappear and I am left with the combined level alone.
Perceived loudness is not the power ratio
For a 10 dB gap, from 70 to 80 in the default comparison, the power ratio is exactly 10, while the perceived-loudness ratio is 2. Those are different calculations on purpose: power follows 10 to the power of the decibel gap divided by 10, and the loudness line follows a doubling for each 10 dB, which is a rule of thumb about hearing rather than a measure of watts. Three sources at 60, 60, and 55 do not land on 63 the way two equal 60 dB sources do. The quieter 55 dB source still adds a fraction of a decibel on top of that 63, because every level is converted to power before the sum, including the smaller one.
Related tools
- Punnett Square Calculator
Build Punnett squares for monohybrid and dihybrid crosses (Aa × Aa, AaBb × AaBb) and get genotype and phenotype ratios and probabilities.
- Dew Point & Humidity Calculator
Calculate the dew point from air temperature and relative humidity — or relative humidity from temperature and dew point — with a comfort rating.
- Ohm's Law Calculator
Enter any two of voltage, current, resistance and power to calculate the other two with Ohm's law and the power formulas.
- Watts, Volts & Amps Calculator (DC, AC, 3-Phase)
Convert between watts, amps and volts for DC, single-phase AC and three-phase circuits, including power factor.
- Torque & Gear Ratio Calculator
Calculate torque from force and lever arm, and a gear train's ratio, output speed and output torque from the tooth counts.
- Sound Level Meter (Decibel Meter)
Measure noise levels with your microphone — live decibel reading, peak, average and a history graph — with calibration and noise-exposure guidance.