Solar Panel Size & Payback Calculator

Estimate how many solar panels and what system size (kW) you need to cover your electricity use, the yearly savings and the payback period.

How to use

  1. 1Enter your monthly electricity use (kWh) and your area's peak sun hours.
  2. 2Enter the panel wattage, system cost per watt, electricity price and any incentive.

How it's calculated

System kW = (monthly kWh × 12 ÷ 365) ÷ sun hours ÷ (1 − losses). Panels = kW × 1000 ÷ panel watts. Payback = net cost ÷ yearly savings.

Frequently asked questions

What are peak sun hours?

The average daily hours of 1,000 W/m² sunlight. They range from about 3 in cloudy northern regions to 6+ in deserts. NREL's PVWatts shows your local value.

What losses should I assume?

About 14% covers inverter, wiring, soiling and temperature losses (PVWatts default).

Is there a US solar tax credit?

The federal residential clean energy credit was 30% of system cost; recent legislation changes eligibility dates, so check the current IRS rules before relying on it.

Why 'peak sun hours' isn't the same as daylight hours

A peak sun hour is the equivalent time spent at a standardized 1,000 W/m² of sunlight — a place with 10 hours of daylight but hazy, low-angle sun for much of it might still only average 4–4.5 peak sun hours, while a shorter but intensely sunny desert day could average 6 or more. That's why sizing a system off peak sun hours (which already account for intensity, angle and typical weather) gives a far more realistic production estimate than simply counting daylight hours.

Worked example: Solar Panel Size & Payback Calculator

A home using 900 kWh/month needs roughly 900 × 12 ÷ 365 ≈ 29.6 kWh a day. Dividing by 4.5 peak sun hours and then by (1 − 14% losses) gives a required system size of about 7.64 kW; rounding up to whole 400W panels means 20 panels (ceil(7.64 × 1000 ÷ 400) = 20), for an actual installed size of exactly 8 kW — slightly more than the bare minimum, since you can't buy a fraction of a panel.

Why that rounding-up is a small free bonus, not waste

Because the panel count always rounds up to a whole number, the installed system is very slightly larger than the exact calculated requirement — in this example, 8 kW of installed capacity against a 7.64 kW calculated need. That small overprovisioning provides a bit of buffer for panel degradation over time (panels typically lose about 0.5% of output per year) and for days when actual sun hours fall short of the long-term average, rather than representing money spent on unneeded capacity.

Savings follow the panels I would actually buy

Monthly use starts at 900 kilowatt-hours, 4.5 peak sun hours, 400 watt panels, 14 percent losses, and 100 percent of usage, which rounds up to 20 panels and 8.0 kilowatts. Yearly production, savings, and payback all use that rounded system, not the fractional kilowatts from before the panel count was raised. An incentive percentage, blank counting as none, comes off the installed cost before payback is cost divided by yearly savings. If the electricity price is zero, savings are zero and the payback does not come back as a normal number of years. Sun hours and panel wattage both have to be greater than zero. The currency menu labels the money; it does not convert a dollar-per-watt cost into another currency.