Insulation R-Value Calculator

Find the recommended attic insulation R-value for your climate zone and how many inches of fiberglass, cellulose or spray foam it takes to get there.

How to use

  1. 1Choose your US climate zone and the insulation type.
  2. 2Enter the R-value (or inches) you already have to see how much to add.

How it's calculated

Inches needed = (target R − existing R) ÷ R per inch. Typical R per inch: fiberglass batts 3.2, blown fiberglass 2.5, blown cellulose 3.5, open-cell spray foam 3.6, closed-cell spray foam 6.5.

Frequently asked questions

What R-value should my attic have?

ENERGY STAR recommends about R-30 to R-49 in the warmest zones and R-49 to R-60 in most of the US.

What is R-value?

Resistance to heat flow — higher is better. R-values of layers add together.

Should I seal air leaks first?

Yes — air sealing around lights, pipes and attic hatches often saves as much energy as the extra insulation.

Sources

Why the recommended R-value depends on climate zone, not a fixed number

Attic insulation's job is slowing heat flow between the living space and the outside, and how much insulation is worth installing depends directly on how large that temperature difference typically gets — which is why ENERGY STAR's recommendation ranges from R-30 in South Florida and Hawaii (Zone 1) up to R-49–R-60 across most of the northern US (Zones 5 and up). Installing Zone-1 levels of insulation in a Zone-7 climate would leave a house under-insulated for its actual winters, while over-insulating a mild climate past the recommended range has rapidly diminishing energy-savings returns for the added cost.

Worked example: Insulation R-Value Calculator

A Zone 5 attic with R-11 of existing insulation (a thin, older layer) falls well short of the recommended R-49 to R-60 minimum. The calculator targets the low end of that range, so it computes 49 − 11 = 38 R-value still needed. Using blown cellulose at 3.5 R-value per inch, that's 38 ÷ 3.5 ≈ 10.86 inches of additional material — across a 1,000 ft² attic floor, that works out to roughly 905 ft³ of cellulose to blow in.

Why R-per-inch varies so much by insulation type

Closed-cell spray foam delivers roughly 6.5 R-value per inch versus blown fiberglass's 2.5 — meaning the same R-38 target needs about 5.8 inches of closed-cell foam versus over 15 inches of blown fiberglass. That difference in density is exactly why foam costs more per board-foot but can reach a target R-value in much less physical depth, which matters directly in attics or wall cavities where depth is physically limited.

Why air sealing is mentioned as a prerequisite, not an afterthought

Insulation slows conductive heat flow through material, but it does nothing to stop air leaking directly through gaps around recessed lights, plumbing penetrations and the attic hatch — and a leaky attic can lose as much energy through air movement as it does through under-insulation. Adding R-value on top of unsealed air leaks is a bit like buying a thicker coat but leaving it unzipped; sealing those gaps first is usually the better dollar-for-dollar energy investment, which is why it's worth doing before, not after, laying new insulation on top of them.

Existing insulation above the minimum means I add nothing

The recommended attic range depends on the climate zone, which opens at zone 5, and the headline shows the low and the high of that range. Inches to add use the minimum of the range, minus whatever existing R-value I typed, and never less than zero. If my existing insulation is already at or above that minimum, the R-value to add and the inches to add are both zero. The insulation type changes how many inches that R-value takes, because each type has its own R per inch. Closed-cell foam needs fewer inches than fiberglass batts for the same R. Volume appears only when the attic area is above zero, as area times the inches, divided by 12, in cubic feet.