Water Heater Size Calculator

Size a tank water heater by peak-hour hot water demand (first-hour rating), or a tankless heater by flow rate and temperature rise.

How to use

  1. 1Enter how many showers, baths and appliances run in your busiest hour.
  2. 2For tankless, enter the flow of fixtures used at once and the incoming water temperature.

How it's calculated

Peak-hour demand ≈ showers × 20 gal + baths × 25 + dishwasher 6 + clothes washer 7 + kitchen sink 4 (DOE estimates). Tankless: flow (gpm) and temperature rise determine kW/BTU: BTU/h = gpm × 500 × ΔT°F.

Frequently asked questions

What is the first-hour rating?

How much hot water a tank heater can deliver in an hour starting full — shown on the EnergyGuide label. Choose one at or above your peak demand.

Why does incoming water temperature matter for tankless?

The heater must raise water from its incoming temperature to about 120 °F. Cold climates need a larger rise and more power.

Is a bigger tank always better?

No — you pay to keep unused water hot. Size for the busiest hour, not the busiest day.

Sources

Why tank and tankless heaters need completely different sizing logic

A tank heater stores hot water in advance, so it's sized for peak-hour demand — the most hot water your household could plausibly use in any single hour, since the tank draws down during that hour and needs to meet the whole demand before it can reheat. A tankless heater makes hot water on demand with no storage buffer at all, so it's sized instead for simultaneous flow rate and how much temperature rise is needed right now — which is why the two halves of this calculator ask for different inputs entirely rather than one number feeding both.

Worked example: Water Heater Size Calculator

A household running 3 showers, 1 dishwasher load and 1 laundry load in its busiest hour needs a first-hour rating of 3×20 + 1×6 + 1×7 = 73 gallons — the minimum a tank heater should be able to deliver starting full. For a tankless heater serving 4 gallons per minute of simultaneous fixtures with incoming water at 50°F (a 70°F rise to reach 120°F), the required capacity is 4 × 500 × 70 = 140,000 BTU/h, or about 41 kW if sized as an electric tankless unit.

Why incoming water temperature changes tankless sizing so much

A tankless heater in a cold climate with 40°F groundwater needs to achieve an 80°F temperature rise to reach 120°F output, while the same heater in a warmer climate with 65°F incoming water only needs a 55°F rise — a 45% difference in required heating power for the identical flow rate. This is why a tankless unit sized correctly for a mild climate can struggle to keep up with multiple fixtures running at once in a cold one; the flow rate alone doesn't tell the whole story without knowing the temperature rise it has to produce.

Why bigger isn't automatically better for a tank heater

The FAQ's point that 'you pay to keep unused water hot' matters more than it might seem: a tank heater maintains its entire stored volume at temperature around the clock through standby heat loss, so oversizing for the busiest possible hour rather than the actual typical peak hour means paying ongoing energy costs to keep gallons hot that rarely get used. Sizing to the real peak-hour demand, not a worst-case guess, keeps that standby loss proportionate to what the household actually needs.